Printers  

 

Beagle Hardware External Printer Driven Buzzer
and Alarm Installation and Setup

The Beagle Hardware Print Alarm works as print alarm. When plugged into the back of an any Epson TM series printer it provides an audible alarm whenever a slip is printed (no cash drawer required). It can also sound an external  alarm , light a light or trigger external devices. With programmable intervals and alarm modes it is our most versatile and useful alarm.

Available Alarm/Relay Functions

P1: Relay On
P2: Relay Off
P3: Cycle relay On/Off
P4: Cycle relay Off/On
P5: Trigger relay On
P6: Trigger relay Off
P7: Trigger Cycle relay On/Off
P8: Trigger Cycle relay Off/On

Time delay range: T1 and T2 between 0.1 seconds to 99 hours adjustable.

P1 (Delay turn off): when power on, the relay on, delay T1, and then the relay off. Default setting.
Give IN a low level, repeat the above function.

P2 (Delay turn on): when power on, the relay disconnected, delay T1, and the relay on.
Give IN a low level, repeat the above function.

P3 (Timing cycle on-off): when power on, the relay on, delay T1, and the relay off, delay T2, the relay on, and then repeat the above condition. Cycle times can be adjusted 1-99 times or infinite loop.

P4 (Timing cycle off-on): when power on, the relay disconnected, delay T1, and the relay on, delay T2, the relay off, and then repeat the above condition. Cycle times can be adjusted 1-99 times or infinite loop.

P5 (Trigger delay turn off): when power on, the relay disconnected, triggered the relay on, delay T1, and the relay off. Give IN a low level, repeat the above function.

P6 (Trigger delay turn on): when power on, the relay disconnected, triggered the relay disconnected, delay T1, and the relay on.
Give IN a low level, repeat the above function.

P7 (Trigger cycle on-off): when power on, the relay disconnected, triggered the relay on, delay T1, and the relay off, delay T2, and the relay on, and then repeat the above condition. Cycle times can be adjusted 1-99 times or infinite loop.

P8 (Trigger cycle off-on): when power on, the relay disconnected, triggered the relay disconnected, delay T1, and the relay on, delay T2, and the relay off, and then repeat the above condition,. Cycle times can be adjusted 1-99 times or infinite loop.

 

Setting  Changes

Step 1: power on.

Step 2: long press the SET key to enter the function to choose, display P1-P8, short press SET key, switch between function P1 to function P8.
Step 3: press the ADD key to select the T1 time unit, the display value (-0/-1/-2/-3), set the T1 time unit, then press the ADD key time unit to switch between -0/-1/-2/-3.

Time unit: -0:time range 0.1s to 9.9s.(time accuracy:0.1s)
Time unit: -1: 1s to 99s.(time accuracy:1s)
Time unit: -2: 1min to 99min.(time accuracy:1min)
Time unit: -3: 1h to 99h.(time accuracy:1h)

Step 4: press the SET key to set T1 time, display T1, then press ADD/Enter key to add and subtract time, display value (00).

If it is a function of P1, P2, P5 and P6, press SET key to confirm the save, set the end.

If it is a function of P3, P4, P7 and P8, to enter the step 5.

Step 5: press the SET key to select the T2 time unit, the display value (-0/-1/-2/-3), set the T2 time unit, then press the ADD key time unit to switch between -0/-1/-2/-3.

Time unit: -0:time range 0.1s to 9.9s.(time accuracy:0.1s)
Time unit: -1: 1s to 99s.(time accuracy:1s)
Time unit: -2: 1min to 99min.(time accuracy:1min)
Time unit: -3: 1h to 99h.(time accuracy:1h)

Step 6: press the SET key to set T2 time, display T2, then press ADD/Enter key to add and subtract time, display value (00).

Step 7: press the SET key to set the cycle times, display "C-", then press the ADD/Enter button to add and subtract the times of cycles, display value (00), if set to 0 is infinite loop.

Step 8: press the SET key to confirm the settings.

 

Specifications

1. working voltage: DC 24V
2. Load Power: DC 0~30V 10A / AC 0~220V 10A.
3. Static current: 15mA
4. Working current: 30mA
5. Service life: 100 thousand times;
6. Working temperature: -40~85℃;
7. Waterproof Level: IP66
8. Case Material: ABS V0
9. Transparent Cover Material: PC V0
10. Dimensions (L*W*H): 5.2 x 2.7 x 1.9 inch (132.2 * 68.7 * 50.1mm)

Setup -  Drawer Driven

Epson/Star
The buzzer is placed in line with the printer. The buzzer simply plugs into the existing power supply connection and then plugs into the power jack on the printer.

 

Setup -Drawer Driven

Epson/Star
The buzzer simply plugs into back of the printer into the cash drawer port. Plug the power cord into the buzzer and the plug the buzzer power plug into the printer.

To buzz send the open drawer command to sound buzzer

The auto-sense version sense the current drawn by the printer to know when it is printing. No connection to the drawer port is needed.

 

 
     
   
  Drawer-Driven Drawer Kick Buzzer Version
$69.95

Buy Bixolon ERC-38 Ribbon Cartridge
BGLBUZZDK

Drawer Kick Relay Version
$99.95

Buy Bixolon ERC-38 Ribbon Cartridge
BGLBUZZDKRL

 

 

More:


Home |  Printers |  Accessories |  Price List |  Service |  Contact
 

30-day guarantee on everything we sell

E-Mail: [email protected]

Call:
800-253-6407

Copyright© 2023 Beagle Hardware

Beagle Hardware is a BBB Accredited Business. Click for the BBB Business Review of this Computers Software & Services in Minneapolis MN